ID | hardware revision | firmware revision | date of production | status | use | notes |
---|---|---|---|---|---|---|
5K6 | 0.1.2 (OPA2830) | unknown | 2020-05-01 | active use | in-field testing | |
10K | 0.1.2 (OPA2830) | unknown | 2020-05-01 | active use | in-field testing | use 10K resistor for feedback on transducer output (testing 3V3 operation) |
001 | 0.1.2 (OPA2830) | unknown | 2020-07-08 | ready | none | |
002 | 0.1.2 (OPA2830) | unknown | 2020-07-08 | ready | none | |
003 | 0.1.2 (OPA2830) | unknown | 2020-07-08 | fail | none | issues with constant velocity spike on FFT at about bin 90, this seems to be caused by the 1 MHz oscillator. The situation is not recoverable without investigating the potted sensor. |
004 | 0.1.2 (OPA2830) | unknown | 2020-07-08 | ready | none | |
005 | 0.1.2 (OPA2830) | unknown | 2020-06-01 | active | Stephen testing/reference |