Human Comfort Supplementary

From BoSL Wiki
Revision as of 01:52, 8 February 2023 by Ari2 (talk | contribs) (→‎Wiring)
Jump to navigation Jump to search

Wiring

Here's the wiring for the human comfort sensor. The connection that we have done are following the cable colors of this chart

If the One wire sensor that is used aren't the parasitic power type, add a 1k resistor between the Data and Vin.

HC Wiring.png


The wind meter requires a desoldering on the original power module that is originally attached to the board. After its being removed, just attached wires to the connector point. The connection for the wires are :

- 5V to pin 1
- GND to pin 2
- Vout to pin 3
Windmeter Board Connector
Windmeter Board.jpg
Windmeter Connector.png

Program Code

Final Program File: File:WeatherStation-nanoLoop0.4.1 - simbase.ino