Difference between revisions of "BoSL Velocity Database"

From BoSL Wiki
Jump to navigation Jump to search
Line 22: Line 22:
 
| 004 || 0.1.1 (OPA2830)|| [[File:BoSL Velocity Firmware 0-1-0.zip]] || 2020-07-08 || active use|| in-field testing SD with SIM5320 IMEI ending: 94075||  
 
| 004 || 0.1.1 (OPA2830)|| [[File:BoSL Velocity Firmware 0-1-0.zip]] || 2020-07-08 || active use|| in-field testing SD with SIM5320 IMEI ending: 94075||  
 
|- id="005"
 
|- id="005"
| 005 || 0.1.1 (OPA2830)|| unknown || 2020-06-01 || active use || Stephen testing/reference ||  
+
| 005 || 0.1.1 (OPA2830)|| [[File:Velocity Firmware rev 0.1.1.zip]] || 2020-06-01 || active use || Stephen testing/reference ||  
 
|- id="006"
 
|- id="006"
 
| 006 || 0.1.1 (OPA2830)|| [[File:BoSL Velocity Firmware 0-1-0.zip]] || 2020-07-13 || active use || in-field testing SD with SIM5320 IMEI ending: 97151 ||  
 
| 006 || 0.1.1 (OPA2830)|| [[File:BoSL Velocity Firmware 0-1-0.zip]] || 2020-07-13 || active use || in-field testing SD with SIM5320 IMEI ending: 97151 ||  
 
|}
 
|}

Revision as of 05:08, 20 July 2020

Since more in water velocity sensors have come into production it is getting more difficult to keep track of specific issues, uses and statuses. This page is created to document that purpose

For specifics about hardware revisions please visit the Design Library

You can link to any particular sensor with the editor text: link text here

ID hardware revision firmware revision date of production status use notes
5K6 0.1.1 (OPA2830) File:BoSL Velocity Firmware 0-1-0.zip 2020-05-01 active use in-field testing
10K 0.1.1 (OPA2830) unknown 2020-05-01 active use in-field testing use 10K resistor for feedback on transducer output (testing 3V3 operation)
001 0.1.1 (OPA2830) File:BoSL Velocity Firmware 0-1-0.zip 2020-07-08 active use in-field testing SD with SIM5320 IMEI ending: 04600
002 0.1.1 (OPA2830) File:BoSL Velocity Firmware 0-1-0.zip 2020-07-08 active use in-field testing SD with SIM5320 IMEI ending: 14401
003 0.1.1 (OPA2830) unknown 2020-07-08 fail none issues with constant velocity spike on FFT at about bin 90, this seems to be caused by the 1 MHz oscillator.

The situation is not recoverable without investigating the PCB of the potted sensor.

004 0.1.1 (OPA2830) File:BoSL Velocity Firmware 0-1-0.zip 2020-07-08 active use in-field testing SD with SIM5320 IMEI ending: 94075
005 0.1.1 (OPA2830) File:Velocity Firmware rev 0.1.1.zip 2020-06-01 active use Stephen testing/reference
006 0.1.1 (OPA2830) File:BoSL Velocity Firmware 0-1-0.zip 2020-07-13 active use in-field testing SD with SIM5320 IMEI ending: 97151