Difference between revisions of "BoSL Board V0.5 Debug"
Line 43: | Line 43: | ||
=== 19 Feb 2024 === | === 19 Feb 2024 === | ||
B5_TurbDepth_3 recovered after stopped logging for 7 days. | B5_TurbDepth_3 recovered after stopped logging for 7 days. | ||
+ | |||
+ | === 20 Feb 2024 === | ||
+ | B5_DT_SD_2 setup not logging for 3 days. Start to log today when connected to PC USB port.<br> | ||
+ | Looks like a board quality issue. |
Revision as of 23:30, 19 February 2024
Contents
Issue List
ATMega issue
Description:
Get no response from BoSL Serial, looks like ATMega is dead. This happened twice on 2 boards.
Test:
The first time, the code used RTC for deep sleep. To exclude the RTC issue, the second
time used watchdog timer for deep sleep.
SIM7000 issue
Description:
When Sim7000 is power on, get no response from Sim7000.
Test:
Tried using different baud rates talk to Sim7000.
Tried keep sending "AT" to Sim7000.
None of the above method work.
After pressing reset button, sim7000 started to response.
Network register issue
Description:
Some boards cannot register to network.
Test:
Tested 6 boards by using same code, 4 of them cannot register to network.
Keep receiving "+CREG: 0,2", resetting sim7000 and re-connecting to battery won't fix it.
Debug history
6th Feb 2024
Yesterday(cloudy) tested 6 BoSL 0.5 boards, and found out 4 of them cannot register to network.
Today(clear day) tested the 4 "problematic" boards again, using the same sim card and same code.
2 of them are easy to register to network, no idea why, the weather?
1 of them cannot register to network at first, even tried "sendATcmd(F("AT+COPS=0"), "OK", 150000, 1);".
but after reconnecting to the battery 2 or 3 times, it was able to register to network.
There is still one board cannot register to network, reconnecting to the battery or await "AT+COPS" for 150s not work.
Adding:
The last board which cannot register to the network started to logging after being connected to battery for about 1 hour,
it looks like the Sim7000 module needs a warm up before work properly.
8th Feb 2024
Stephen got the same network register issue with BoSL 0.5 board today.
He tested sending ATCommand "AT+CEREG=1" and got the network registered.
We can test this ATCommand on more boards that have the same issue.
19 Feb 2024
B5_TurbDepth_3 recovered after stopped logging for 7 days.
20 Feb 2024
B5_DT_SD_2 setup not logging for 3 days. Start to log today when connected to PC USB port.
Looks like a board quality issue.