Difference between revisions of "BoSL Velocity Database"

From BoSL Wiki
Jump to navigation Jump to search
Line 7: Line 7:
 
{| class="wikitable sortable"
 
{| class="wikitable sortable"
 
|-  
 
|-  
! ID !! hardware revision !! firmware revision !! date of production !! status!! use !! notes
+
! ID !! hardware revision !! firmware revision !! date of production !! status!! use !! calibration !! notes  
 
|- id="5K6"
 
|- id="5K6"
| 5K6|| 0.1.1 (OPA2830)|| [[File:Velocity_Firmware_rev_0.1.3.zip]]|| 2020-05-01|| active use|| in-field testing||  
+
| 5K6|| 0.1.1 (OPA2830)|| [[File:Velocity_Firmware_rev_0.1.3.zip]]|| 2020-05-01|| active use|| not recorded || in-field testing||  
 
|- id="10K"
 
|- id="10K"
| 10K || 0.1.1 (OPA2830) || unknown || 2020-05-01|| active use || in-field testing|| use 10K resistor for feedback on transducer output (testing 3V3 operation)
+
| 10K || 0.1.1 (OPA2830) || unknown || 2020-05-01|| active use || in-field testing || not recorded|| use 10K resistor for feedback on transducer output (testing 3V3 operation)
 
|- id="001"
 
|- id="001"
| 001 || 0.1.1 (OPA2830)|| [[File:BoSL Velocity Firmware 0-1-0.zip]]|| 2020-07-08 || active use || in-field testing SD with SIM5320 IMEI ending: 04600||  
+
| 001 || 0.1.1 (OPA2830)|| [[File:BoSL Velocity Firmware 0-1-0.zip]]|| 2020-07-08 || active use || not recorded|| in-field testing SD with SIM5320 IMEI ending: 04600||  
 
|- id="002"
 
|- id="002"
| 002 || 0.1.1 (OPA2830)|| [[File:BoSL Velocity Firmware 0-1-0.zip]]|| 2020-07-08 || active use || in-field testing SD with SIM5320 IMEI ending: 14401||  
+
| 002 || 0.1.1 (OPA2830)|| [[File:BoSL Velocity Firmware 0-1-0.zip]]|| 2020-07-08 || active use || not recorded|| in-field testing SD with SIM5320 IMEI ending: 14401||  
 
|- id="003"
 
|- id="003"
| 003 || 0.1.1 (OPA2830)|| unknown || 2020-07-08 || fail || none || issues with constant velocity spike on FFT at about bin 90, this seems to be caused by the 1 MHz oscillator.  
+
| 003 || 0.1.1 (OPA2830)|| unknown || 2020-07-08 || fail || none || not recorded|| issues with constant velocity spike on FFT at about bin 90, this seems to be caused by the 1 MHz oscillator.  
 
The situation is not recoverable without investigating the PCB of the potted sensor.   
 
The situation is not recoverable without investigating the PCB of the potted sensor.   
 
|- id="004"
 
|- id="004"
| 004 || 0.1.1 (OPA2830)|| [[File:BoSL Velocity Firmware 0-1-0.zip]] || 2020-07-08 || active use|| in-field testing SD with SIM5320 IMEI ending: 94075||  
+
| 004 || 0.1.1 (OPA2830)|| [[File:BoSL Velocity Firmware 0-1-0.zip]] || 2020-07-08 || active use|| not recorded|| in-field testing SD with SIM5320 IMEI ending: 94075||  
 
|- id="005"
 
|- id="005"
| 005 || 0.1.1 (OPA2830)|| [[File:Velocity Firmware rev 0.1.1.zip]] || 2020-06-01 || active use || Stephen testing/reference ||  
+
| 005 || 0.1.1 (OPA2830)|| [[File:Velocity Firmware rev 0.1.1.zip]] || 2020-06-01 || active use || not recorded|| Stephen testing/reference ||  
 
|- id="006"
 
|- id="006"
| 006 || 0.1.1 (OPA2830)|| [[File:BoSL Velocity Firmware 0-1-0.zip]] || 2020-07-13 || active use || in-field testing SD with SIM5320 IMEI ending: 97151 ||  
+
| 006 || 0.1.1 (OPA2830)|| [[File:BoSL Velocity Firmware 0-1-0.zip]] || 2020-07-13 || active use || not recorded|| in-field testing SD with SIM5320 IMEI ending: 97151 ||  
 
|- id="007"
 
|- id="007"
| 007 || 0.1.3|| unknown || 2020-08-11 || unused|| -- ||  
+
| 007 || 0.1.3|| unknown || 2020-08-11 || unused || not recorded || -- ||  
 
|- id="008"
 
|- id="008"
 
| 008 || 0.1.3|| [[File:Velocity Firmware rev 0.1.3 ID008.zip]]|| 2020-09-09 || inlab || -- ||  
 
| 008 || 0.1.3|| [[File:Velocity Firmware rev 0.1.3 ID008.zip]]|| 2020-09-09 || inlab || -- ||  

Revision as of 10:31, 28 September 2020

Since more in water velocity sensors have come into production it is getting more difficult to keep track of specific issues, uses and statuses. This page is created to document that purpose

For specifics about hardware revisions please visit the Design Library

You can link to any particular sensor with the editor text: link text here

ID hardware revision firmware revision date of production status use calibration notes
5K6 0.1.1 (OPA2830) File:Velocity Firmware rev 0.1.3.zip 2020-05-01 active use not recorded in-field testing
10K 0.1.1 (OPA2830) unknown 2020-05-01 active use in-field testing not recorded use 10K resistor for feedback on transducer output (testing 3V3 operation)
001 0.1.1 (OPA2830) File:BoSL Velocity Firmware 0-1-0.zip 2020-07-08 active use not recorded in-field testing SD with SIM5320 IMEI ending: 04600
002 0.1.1 (OPA2830) File:BoSL Velocity Firmware 0-1-0.zip 2020-07-08 active use not recorded in-field testing SD with SIM5320 IMEI ending: 14401
003 0.1.1 (OPA2830) unknown 2020-07-08 fail none not recorded issues with constant velocity spike on FFT at about bin 90, this seems to be caused by the 1 MHz oscillator.

The situation is not recoverable without investigating the PCB of the potted sensor.

004 0.1.1 (OPA2830) File:BoSL Velocity Firmware 0-1-0.zip 2020-07-08 active use not recorded in-field testing SD with SIM5320 IMEI ending: 94075
005 0.1.1 (OPA2830) File:Velocity Firmware rev 0.1.1.zip 2020-06-01 active use not recorded Stephen testing/reference
006 0.1.1 (OPA2830) File:BoSL Velocity Firmware 0-1-0.zip 2020-07-13 active use not recorded in-field testing SD with SIM5320 IMEI ending: 97151
007 0.1.3 unknown 2020-08-11 unused not recorded --
008 0.1.3 File:Velocity Firmware rev 0.1.3 ID008.zip 2020-09-09 inlab --
009 0.1.3 unknown 2020-09-09 inlab --
010 0.1.3 unknown 2020-09-09 inlab --
011 0.1.3 unknown 2020-09-09 inlab --
012 0.1.3 unknown 2020-09-09 inlab --
013 0.1.3 unknown 2020-09-09 inlab --